Probably it never existed a 1081 official service manual from Commodore, it's look more like a NAPCEC service manual & diagrams compilation of the 1084 series and his variants, like the nap6523, 8cm505, 1084S, 1084P and obviously the 1081. It's more complete than other scans and the quality of the scans also are far superior. It has two circuit diagrams variants of the 1081, mono and stereo versions. It doesn't include a diagram for the Philips CM8500 or CM8501, they look like the 1081 but they are slightly different.
;
Rapid, clear well done as all the scheme I downloaded from this site. Great job very functional and very useful
8.5.
Sleep Mode Auto Operation
Cooling or Soft Dry Operation
When you press the SLEEP Mode, the following movement will start to avoid overcooling. � The fan speed refer to Indoor Fan Motor Control. � The setting temperature will be risen by 0.5°C at the start of operation and by 0.5°C one hour later. � The operation will stop after 8 hours. � When using together with the Timer, the ON-Timer has priority.
Heating Operation When you press the SLEEP Mode, the following movement will start to avoid overheating. � The fan speed refer to Indoor Fan Motor Control. � The setting temperature will be descented by 2°C at the start of operation and by 3°C one hour later. � The operation will stop after 8 hours. � When using together with the Timer, the ON-Timer has priority.
8.6.
Auto Restart Control
� If there is a power failure, operation will be automatically restarted when the power is resumed. It will start with previous operation mode and airflow direction. (Time Delay Safety Control is valid) � Auto Restart Control is not available when Timer or Sleep Mode is set. � This control can be omitted by cutting the jumper wire J2. (Refer Circuit Diagram)
8.7.
Indoor Fan Speed Control
� Auto Fan Speed Control When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table. � Manual Fan Speed Control Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button.
Fan Speed Cooling Soft Dry Manual Auto Sleep Manual, Auto Sleep Manual Auto Sleep O O O O High Speed �� Low Speed O O O O O O O O O O O O Lo SLo SSLo
O O
Heating
O O Hi
O O Me
O STOP
|
|
|
> |
|